The thermal diffusivity of carbon fiber materials are measured by infrared imaging technology and reverse heat conductance method here. Experimental data are processed by multiple linear regression and the influential fac2 tors of the accuracy are analyzed. The results show that the thermal diffusivity of the carbon fiber materials can be measured conveniently by this technology ,and the method is feasible.