The conflict of longevity of satellites service and limited life of Sterling coolers decides that coolers should work on the intermittent mode in space. As a result, detectors in satellite are commonly subjected to thousands of repeated thermal cycles from below 173℃ to room temperature (20℃), which brings new reliability problems. This paper introduced a new thermal cycle automatic system, detector was cooled by liquid N2, temperature range was 295K to 100K. Reliability of two types of detector was studied with this equipment. Resistance, signal and noise were measured and summarized before and after experiment. The results were analyzed and explained. It would be referenced for the fabrication of detectors.