    摘要:

    相对于传统直接测试探测灵敏度的方法,提出了基于探测概率曲线的探测灵敏度测试方法,详细阐述了测试方法和步骤以及数据处理方法。按照上述方法,对某高性能激光探测接收机的探测灵敏度进行了测试,测试过程及结果表明,该方法在操作的简便性和测试结果的准确度上均优于传统测试方法。

    Abstract:

    Compared to traditional test mode,a novel detection sensitivity test mothod based on probability curve is brought forward,the test method and procedure and the data-processing algorithm is represented.According to this test mothod,detection sensitivity is tested for one laser detector with high performance,the operating procedure and results prove that the novel method is better than the traditional in convenience and accuracy.