Digital holographic interferometry is used to measure the temperature distribution of airflow field.A fast Fourier transform followed by a digital low-pass filter and an inverse Fourier transform are applied to interference fringes for removing speckle noise,so that airflow field phase information is in high-contrast and low noise.Phase is unwrapped to calculate phase difference.The temperature distribution is obtained by the relation between phase and refractive index.The results are consistent with the values measured by thermocouple.It is shown that the digital holographic interferometry is an effective method for measuring temperature field and the measuring precision can be greatly improved.
参考文献
相似文献
引证文献
引用本文
周战荣.实时数字全息测量温度场研究[J].激光与红外,2011,41(8):916~919 ZHOU Zhan-rong. Measuring temperature field with real-time digital holographic interferometry[J]. LASER & INFRARED,2011,41(8):916~919