    摘要:

    红外整机成像时需要对红外探测器的输出进行非均匀校正,来获得相对均匀可观的图像。在一款碲镉汞长波红外探测器整机成像实验时,图像出现了 “暗环”现象,通过分析确认了“暗环”现象的机理,并通过优化改进,消除了成像“暗环”,为其他长波红外探测器成像应用提供了借鉴。

    Abstract:

    Infrared imaging requires non uniform correction of the output of the infrared detector to obtain a relatively uniform and impressive image.The dark ring phenomenon occurs during the imaging process of long wave infrared HgCdTe detector systems,and the mechanism is confirmed through analysis,and the imaging dark ring is eliminated through optimization and improvement.This method serves as a valuable reference for other applications utilizing long wave infrared detectors in imaging.

    参考文献
    相似文献
    引证文献
引用本文

李娟,高璐,陈彦冠,付志凯,张磊.碲镉汞长波红外探测器成像暗环研究[J].激光与红外,2025,55(4):575~578
LI Juan, GAO Lu, CHEN Yan-guan, FU Zhi-kai, ZHANG Lei. Research on dark ring imaging in long wave infrared HgCdTe detectors[J]. LASER & INFRARED,2025,55(4):575~578